Channel Handling
Number of output channels 8 mono
bridgeable per ch. pair
Number of input channels:
Analog 8 (8x XLR)
AES3 8 (4x XLR)
Dante™* 16 (2x RJ45)
* DANTE version only
Audio
Gain 17 dB - 47 dB
(0.1 dB increments)
Default Gain 32 dB
Output Noise
A-Weighted @ 8 Ω - Analog to Analog / Digital to Analog < -70.0 dBV
Dynamic Range
A-Weighted @ 8 Ω - Analog to Analog / Digital to Analog 114,3 dB
Damping Factor @ 8 Ω, 20Hz - 500Hz > 5000
Slew Rate (input filter bypassed) > 50 V/µs
Frequency Response ( -3 dB , 1 W @ 8 Ω) 5 Hz - 30 kHz
Crosstalk (1 kHz) -70 dB
THD+N (from 0.1 W to Full Power) < 0.5%
(typical < 0.01%)
DIM (from 0.1 W to Full Power) < 0.5%
(typical < 0.01%)
Input Impedance 20 kΩ Balanced
Input Acceptance +27 dBu
Output Stage
Maximum output power per channel @ 8 Ω 1600 W
Maximum output power per channel @ 4 Ω 3000 W
Maximum output power per channel @ 2.7 Ω 4000 W
Maximum output power per channel @ 2 Ω 5200 W
Maximum output power @ 8 Ω Bridged 6000 W
Maximum output power @ 4 Ω Bridged 10400 W
Peak total output, all channels driven 40000 W
Maximum unclipped output voltage 175 Vpeak
Maximum output current 130 Apeak
The power figure is calculated by driving and loading symmetrically all the channels: uneven
loads allow to achieve a higher performance.
AC Mains Power
Single Phase
Nominal Voltage 100 - 240 V @ 50/60Hz
Operating Range 90 - 264 V from DC to 200 Hz
Power Factor
1/8 Maximum Output Power1 >0.9
Current Draw
1/8 Maximum Output Power1
32 Arms
@100V
18 Arms
@240V
Suggested circuit breaker C32
Three Phase
Nominal Voltage 173Y / 100 - 416Y / 240 V
3~, 3W+N+PE / 3W+PE
Current Drawn from Each Single Phase
1/8 Maximum Output Power1
12 Arms
@ 173Y
6 Arms
@ 416Y
Suggested circuit breaker (per phase) C16
Idle Consumption (all AC MAINS cases) < 200 W
Max consumption (all AC MAINS cases) < 5000 W
1
1/8 Maximum Output Power into a typical 4 Ω loudspeaker
DSP
AD converters Dual 24 bit 48 kHz Tandem®
architecture
with 129 dBA of dynamic range
DA converters Dual 24 bit 48 kHz Tandem®
architecture
with 121 dBA of dynamic range
Sample rate converter 24 Bit @ 44.1 kHz to 192 kHz
140 dB Dynamic Range - 0.0001 % THD+N
Internal precision 40 bit floating point
Delay up to 2 s on input section
up to 100 ms per output for time alignment
Equalizer
Raised-cosine, custom FIR, parametric IIR:
peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Crossover Linear phase (FIR), hybrid (FIR-IIR), Butterworth, Linkwitz-Riley,
Bessel: 6 dB/oct to 48 dB/oct (IIR)
Limiters TruePower™, RMS voltage, RMS current, Peak limiter
Damping control Active DampingControl™
Thermal
Operating temperature 0° - 35°C / 32° - 95°F
Cooling Fan, continuously variable speed,
temperature controlled
Fan Noise - 1/8 Maximum Output Power @ 8Ω (1m) 40 dBA SPL
Thermal dissipation
Single phase 115V 230V