DYNAMIC EFFECTS
Variable strobe: 0 - 650 ms (50 Hz supply), or 0 - 530 ms (60 Hz supply)
Strobe rate: 0 - 25 flashes/second (50 Hz supply), 0 - 30 flashes/second (60 Hz supply)
Strobe intensity: Blackout - maximum
Blinder effect: Continuous with auto fade
Special effects: Ramp up, ramp down, ramp up-down, random flash, lightning, spikes, blinder, single flash
CONTROL AND PROGRAMMING
Stand-alone control: Via N.O. or N.C. SPST switch
Control options: DMX, stand-alone, multi-fixture chase (with Detonator remote), MC-1
Setting and addressing: DIP switch
Stand-alone options: Selectable flash rate or blinder effect
DMX channels: 1, 3, and 4 channel modes
Receiver: RS-485
DMX compliance: USITT DMX512/1990
LAMP
Type: Xenon discharge
Approved lamps: MAX-15 Xenon (200-240 V power), MAX-7 Xenon (100-120 V power)